Bon Secour Station
 
Location: Bon Secour
Latitude: 30°19.726'N
Longitude 87°49.756'W
 
Meteorological Instrumentation
Sensor Sensor Type Range Accuracy Resolution Height
Wind Speed and Direction R.M. Young
Wind Monitor 05103-L
0-134 mph +/- 0.6 mph 0.1 mph  
Temperature Campbell Scientific
Temperature and Relative Humidity Probe HC2S3
-50°C to +100°C <+/- 0.1°C with standard configuration settings 0.1°C  
Photosythetically Active Radiation Li-Cor
Quantum Sensor LI-190SB
10,000 µmol /s/m2 +/- 5% 1 µE/m2/s  
Total Solar Radiation Li-Cor
Pyronometer LI-200X
0 to 3000 W/m2 Max +/-5%, +/-3% typical in natural daylight 0.01 kW/m2  
Barometric Pressure Vaisala
Barometer PTB101B
600 to 1060 mb +/- 0.5 mb at 20ºC 0.01 mb  
Precipitation Texas Electronics
Tipping Bucket Rain Guage TR-525
Up to 2 in/hour 1.0% at 1 in/hour or less 0.01 in  
Relative Humidity Campbell Scientific
Temperature and Relative Humidity Probe HC2S3
0 to 100% non-condensing +/-0.8% RH with standard configuration settings 0.1% RH  
 
Hydrographical Instrumentation
Sensor Sensor Type Range Accuracy Resolution
Temperature YSI EXO2
Thermistor
-5 to 50° C +/-0.2° C 0.001° C
Dissolved Oxygen percent YSI EXO2
Optical Luminescence
0 to 500% air saturation 0-200% air saturation, +/- 1% of the reading or 1% air saturation, whichever is greater; 200-500% air saturation, +/- 5% of reading 0.1% air saturation
Dissolved Oxygen mg/L YSI EXO2
ROX Optical Luminescence
0 to 50 mg/L 0-20 mg/L, +/- 1% of the reading or 0.1 mg/L, whichever is greater; 20-50 mg/L, +/- 5% of reading 0.01 mg/L
Salinity YSI EXO2
Calculated from conductivity and temperature
0 to 70 ppt +/- 1.0% of reading or 0.1 ppt, whichever is greater 0.01 ppt
Vented level YSI EXO2
Stainless Steel Strain Gauge
0 to 33 ft +/-0.013ft or +/- 0.004m 0.001 ft (0.001m)
Turbidity YSI EXO2
Optical, 90° Scatter w/ Mechanical cleaning
0-4000FNU 0-999 FNU: 0.3 FNU or+/-2% of reading, whichever is greater; 1000-4000 FNU: +/-5% of reading. 0.01FNU
Conductivity YSI EXO2
4-electrode nickle cell
0 to 200 mS/cm +/- 1.0% of reading +0.002 mS/cm 0.0001 mS/cm to 0.01 mS/cm (range dependent)